Waveguide VNA Calibration Kits From Maury Microwave 3H001 Standard Industrial Products
Waveguide VNA Calibration Kits From Maury Microwave
7005E Standard Kits
Features
1.12 to 50 GHz
WR650 Through WR22
Fixed and Sliding Load Calibration
Agilent, Anritsu and Rohde & Schwarz
VNAs Supported
The Importance of VNA Calibration
Any uncalibrated test setup has systematic errors inherent in the equipment used. The ability to obtain an accurate measurement of a device under test. The basis of network analyzer error correction is the measurement of known electrical standards, such as a thru, open circuit, short circuit, and precision load impedance. By calibrating your network analyzer with these standards, you can compensate for the inherent imperfections.
Components of a Maury P7005E17 WR62 cal kit stand ready to perform one-port SSL waveguide calibration measurements on an Agilent PNA (in background). To view a short online demonstration video of this calibration method go to http://maurymw.com/Support/demos.php.
Description
The 7005E Standard Waveguide Calibration Kits are designed to provide accurate calibration of vector network analyzers (VNAs) that are used for measurements in standard rectangular waveguide from 1.12 to 50 GHz (WR650–WR22). Each kit includes all the components needed for accurate calibration of most VNAs with a user-specified set of adapters and a high precision sliding termination (in a machined housing) to ensure high effective directivity after calibration. Precision straight sections and a fixed (reference plane) short are also provide as verification standards
Flange Description
The components in these kits are equipped with Maury Precision Flanges (MPF) which conform to EIA WR standards for rectangular or round waveguide flanges. MPF flanges have precision indexing holes and corresponding indexing pins for precise alignment when mating, which ensures excellent measurement repeatability. Flange diagrams and other details can be found at http://www.maurymw.com. (Use the search feature with search term “MPF”.)
Calibration Methods
These kits are configured for use in performing one-port SSL (Short-Short-Load) calibrations for measuring VSWR/Return Loss, or full two-port SSLT (Short-Short-Load-Thru) calibrations to perform forward and reverse transmission and reflection measurements.
Components Included in 7005E Kits
QUANTITY |
DESCRIPTION |
MODEL |
|
|
|
1 |
Fixed flush (reference plane) short |
344 series |
1 |
|